prsctrl.measurement.settings.MeasurementParameters#

class MeasurementParameters(measurement_time_s: float = 30, wait_time_s: Optional[float] = None, additional_wait_time_s: float = 0, pump_source: str = 'none', pump_power_mWcm2: Optional[float] = None, auto_gain: bool = False, auto_sensitivity: bool = True, wavelengths_nm: Union[tuple[float, float, float], list[float], NoneType] = None, energies_eV: Union[tuple[float, float, float], list[float], NoneType] = None, offset_strategy: Literal['none', 'start-end', 'time-interval'] = 'time-interval', offset_intervals_minutes: list[int] = <factory>)[source]#

Bases: SettingsClass

Methods

as_dict

Convenience wrapper for dataclasses.asdict(self)

copy

Convenience method for copy.deepcopy(self)

fields

Return a tuple describing the fields of this dataclass.

from_dict

Recursively construct a SettingsClass from a dictionary.

get_dict

Return the settings as a dictionary.

get_metadata

Return the measurements settings converted to a metadata dictionary that contains only relevant information.

get_wavelengths_nm

Generate a list of wavelengths according to either the 'wavelengths_nm' or 'energies_eV' field.

get_wavelengths_nm_with_offsets

Generate a list of wavelengths according to either the 'wavelengths_nm' or 'energies_eV' field and offset measurements.

load_yaml

save_yaml

Attributes

__annotations__ = {'additional_wait_time_s': <class 'float'>, 'auto_gain': <class 'bool'>, 'auto_sensitivity': <class 'bool'>, 'energies_eV': typing.Union[tuple[float, float, float], list[float], NoneType], 'measurement_time_s': <class 'float'>, 'offset_intervals_minutes': list[int], 'offset_strategy': typing.Literal['none', 'start-end', 'time-interval'], 'pump_power_mWcm2': typing.Optional[float], 'pump_source': <class 'str'>, 'wait_time_s': typing.Optional[float], 'wavelengths_nm': typing.Union[tuple[float, float, float], list[float], NoneType]}#
__dataclass_fields__ = {'additional_wait_time_s': Field(name='additional_wait_time_s',type=<class 'float'>,default=0,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds to wait for the signal to stabilize after changing the wavelength.\nSet to `0` for no wait time, and to `None` to automatically choose a value based on the lock-in time constant.', 'valid': (0, 999999)}),kw_only=False,_field_type=_FIELD), 'auto_gain': Field(name='auto_gain',type=<class 'bool'>,default=False,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Whether to automatically adjust the gain during the measurement to stay in the optimum DC region. Not current implemented yet.'}),kw_only=False,_field_type=_FIELD), 'auto_sensitivity': Field(name='auto_sensitivity',type=<class 'bool'>,default=True,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Whether to automatically increase the lock-in sensitivity on overloads.'}),kw_only=False,_field_type=_FIELD), 'energies_eV': Field(name='energies_eV',type=typing.Union[tuple[float, float, float], list[float], NoneType],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Energy range in eV. Must be either a list of values or a tuple (start, stop, step). Only one of ``wavelengths_nm`` or ``energies_eV`` may be set.', 'metadatas': {'tuple': {'metadatas': ({'decimals': 3, 'default': 1.55}, {'decimals': 3, 'default': 2.8}, {'decimals': 3, 'default': 0.005}), 'labels': ('[Start', 'Stop)', 'Step')}, 'list': {'metadatas': {'decimals': 3}}}}),kw_only=False,_field_type=_FIELD), 'measurement_time_s': Field(name='measurement_time_s',type=<class 'float'>,default=30,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds where data is recorded at each wavelength.', 'valid': (0, 9999999)}),kw_only=False,_field_type=_FIELD), 'offset_intervals_minutes': Field(name='offset_intervals_minutes',type=list[int],default=<dataclasses._MISSING_TYPE object>,default_factory=<function MeasurementParameters.<lambda>>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': "How many minutes to wait after the last offset measurement. The last interval is repeated indefinetely.\nOnly applies when offset_strategy='time-interval'.\nStart and end offsets are always recorded, unless offset_strategy='none'."}),kw_only=False,_field_type=_FIELD), 'offset_strategy': Field(name='offset_strategy',type=typing.Literal['none', 'start-end', 'time-interval'],default='time-interval',default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Which offset reduction strategy to use. Determines where offset measurements are added.'}),kw_only=False,_field_type=_FIELD), 'pump_power_mWcm2': Field(name='pump_power_mWcm2',type=typing.Optional[float],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Power in mW/cm^2. If ``pump_source`` is set and a conversion table exists for the source then the ``power_mW`` setting for lasers or the `current_A` setting for LEDs can be overwritten with the value corresponding to the ``power_mWcm2`` setting.'}),kw_only=False,_field_type=_FIELD), 'pump_source': Field(name='pump_source',type=<class 'str'>,default='none',default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': "String describing which pump source is used.\nIf 'led', then the values from :py:attr:`PrsSettings.led` are applied. If 'laser', then the values from :py:attr:`PrsSettings.laser` are applied.", 'valid': ['laser', 'led', 'laser-manual', 'led-manual', 'none', 'manual']}),kw_only=False,_field_type=_FIELD), 'wait_time_s': Field(name='wait_time_s',type=typing.Optional[float],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds to wait for the signal to stabilize after changing the wavelength.\nSet to `0` for no wait time, and to `None` to automatically choose a value based on the lock-in time constant.', 'valid': (0, 999999)}),kw_only=False,_field_type=_FIELD), 'wavelengths_nm': Field(name='wavelengths_nm',type=typing.Union[tuple[float, float, float], list[float], NoneType],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Wavelength range in nm. Must be either a list of values or a tuple (start, stop, step). Only one of ``wavelengths_nm`` or ``energies_eV`` may be set.', 'metadatas': {'tuple': {'metadatas': ({'decimals': 3, 'default': 420}, {'decimals': 3, 'default': 800}, {'decimals': 3, 'default': 1}), 'labels': ('[Start', 'Stop)', 'Step')}, 'list': {'metadatas': {'decimals': 3}}}}),kw_only=False,_field_type=_FIELD)}#
__dataclass_params__ = _DataclassParams(init=True,repr=True,eq=True,order=False,unsafe_hash=False,frozen=False,match_args=True,kw_only=False,slots=False,weakref_slot=False)#
__dict__ = mappingproxy({'__module__': 'prsctrl.measurement.settings', '__firstlineno__': 44, '__annotations__': {'measurement_time_s': <class 'float'>, 'wait_time_s': typing.Optional[float], 'additional_wait_time_s': <class 'float'>, 'pump_source': <class 'str'>, 'pump_power_mWcm2': typing.Optional[float], 'auto_gain': <class 'bool'>, 'auto_sensitivity': <class 'bool'>, 'wavelengths_nm': typing.Union[tuple[float, float, float], list[float], NoneType], 'energies_eV': typing.Union[tuple[float, float, float], list[float], NoneType], 'offset_strategy': typing.Literal['none', 'start-end', 'time-interval'], 'offset_intervals_minutes': list[int]}, 'measurement_time_s': 30, 'wait_time_s': None, 'additional_wait_time_s': 0, 'pump_source': 'none', 'pump_power_mWcm2': None, 'auto_gain': False, 'auto_sensitivity': True, 'wavelengths_nm': None, 'energies_eV': None, 'offset_strategy': 'time-interval', 'get_wavelengths_nm': <function MeasurementParameters.get_wavelengths_nm>, 'get_wavelengths_nm_with_offsets': <function MeasurementParameters.get_wavelengths_nm_with_offsets>, 'get_metadata': <function MeasurementParameters.get_metadata>, '__static_attributes__': ('energies_eV', 'wavelengths_nm'), '__doc__': "MeasurementParameters(measurement_time_s: float = 30, wait_time_s: Optional[float] = None, additional_wait_time_s: float = 0, pump_source: str = 'none', pump_power_mWcm2: Optional[float] = None, auto_gain: bool = False, auto_sensitivity: bool = True, wavelengths_nm: Union[tuple[float, float, float], list[float], NoneType] = None, energies_eV: Union[tuple[float, float, float], list[float], NoneType] = None, offset_strategy: Literal['none', 'start-end', 'time-interval'] = 'time-interval', offset_intervals_minutes: list[int] = <factory>)", '__dataclass_params__': _DataclassParams(init=True,repr=True,eq=True,order=False,unsafe_hash=False,frozen=False,match_args=True,kw_only=False,slots=False,weakref_slot=False), '__dataclass_fields__': {'measurement_time_s': Field(name='measurement_time_s',type=<class 'float'>,default=30,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds where data is recorded at each wavelength.', 'valid': (0, 9999999)}),kw_only=False,_field_type=_FIELD), 'wait_time_s': Field(name='wait_time_s',type=typing.Optional[float],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds to wait for the signal to stabilize after changing the wavelength.\nSet to `0` for no wait time, and to `None` to automatically choose a value based on the lock-in time constant.', 'valid': (0, 999999)}),kw_only=False,_field_type=_FIELD), 'additional_wait_time_s': Field(name='additional_wait_time_s',type=<class 'float'>,default=0,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Time in seconds to wait for the signal to stabilize after changing the wavelength.\nSet to `0` for no wait time, and to `None` to automatically choose a value based on the lock-in time constant.', 'valid': (0, 999999)}),kw_only=False,_field_type=_FIELD), 'pump_source': Field(name='pump_source',type=<class 'str'>,default='none',default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': "String describing which pump source is used.\nIf 'led', then the values from :py:attr:`PrsSettings.led` are applied. If 'laser', then the values from :py:attr:`PrsSettings.laser` are applied.", 'valid': ['laser', 'led', 'laser-manual', 'led-manual', 'none', 'manual']}),kw_only=False,_field_type=_FIELD), 'pump_power_mWcm2': Field(name='pump_power_mWcm2',type=typing.Optional[float],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Power in mW/cm^2. If ``pump_source`` is set and a conversion table exists for the source then the ``power_mW`` setting for lasers or the `current_A` setting for LEDs can be overwritten with the value corresponding to the ``power_mWcm2`` setting.'}),kw_only=False,_field_type=_FIELD), 'auto_gain': Field(name='auto_gain',type=<class 'bool'>,default=False,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Whether to automatically adjust the gain during the measurement to stay in the optimum DC region. Not current implemented yet.'}),kw_only=False,_field_type=_FIELD), 'auto_sensitivity': Field(name='auto_sensitivity',type=<class 'bool'>,default=True,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Whether to automatically increase the lock-in sensitivity on overloads.'}),kw_only=False,_field_type=_FIELD), 'wavelengths_nm': Field(name='wavelengths_nm',type=typing.Union[tuple[float, float, float], list[float], NoneType],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Wavelength range in nm. Must be either a list of values or a tuple (start, stop, step). Only one of ``wavelengths_nm`` or ``energies_eV`` may be set.', 'metadatas': {'tuple': {'metadatas': ({'decimals': 3, 'default': 420}, {'decimals': 3, 'default': 800}, {'decimals': 3, 'default': 1}), 'labels': ('[Start', 'Stop)', 'Step')}, 'list': {'metadatas': {'decimals': 3}}}}),kw_only=False,_field_type=_FIELD), 'energies_eV': Field(name='energies_eV',type=typing.Union[tuple[float, float, float], list[float], NoneType],default=None,default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Energy range in eV. Must be either a list of values or a tuple (start, stop, step). Only one of ``wavelengths_nm`` or ``energies_eV`` may be set.', 'metadatas': {'tuple': {'metadatas': ({'decimals': 3, 'default': 1.55}, {'decimals': 3, 'default': 2.8}, {'decimals': 3, 'default': 0.005}), 'labels': ('[Start', 'Stop)', 'Step')}, 'list': {'metadatas': {'decimals': 3}}}}),kw_only=False,_field_type=_FIELD), 'offset_strategy': Field(name='offset_strategy',type=typing.Literal['none', 'start-end', 'time-interval'],default='time-interval',default_factory=<dataclasses._MISSING_TYPE object>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': 'Which offset reduction strategy to use. Determines where offset measurements are added.'}),kw_only=False,_field_type=_FIELD), 'offset_intervals_minutes': Field(name='offset_intervals_minutes',type=list[int],default=<dataclasses._MISSING_TYPE object>,default_factory=<function MeasurementParameters.<lambda>>,init=True,repr=True,hash=None,compare=True,metadata=mappingproxy({'doc': "How many minutes to wait after the last offset measurement. The last interval is repeated indefinetely.\nOnly applies when offset_strategy='time-interval'.\nStart and end offsets are always recorded, unless offset_strategy='none'."}),kw_only=False,_field_type=_FIELD)}, '__replace__': <function _replace>, '__hash__': None, '__init__': <function MeasurementParameters.__init__>, '__repr__': <function MeasurementParameters.__repr__>, '__eq__': <function MeasurementParameters.__eq__>, '__match_args__': ('measurement_time_s', 'wait_time_s', 'additional_wait_time_s', 'pump_source', 'pump_power_mWcm2', 'auto_gain', 'auto_sensitivity', 'wavelengths_nm', 'energies_eV', 'offset_strategy', 'offset_intervals_minutes')})#
__eq__(other)#

Return self==value.

__firstlineno__ = 44#
__hash__ = None#
__init__(measurement_time_s: float = 30, wait_time_s: float | None = None, additional_wait_time_s: float = 0, pump_source: str = 'none', pump_power_mWcm2: float | None = None, auto_gain: bool = False, auto_sensitivity: bool = True, wavelengths_nm: tuple[float, float, float] | list[float] | None=None, energies_eV: tuple[float, float, float] | list[float] | None=None, offset_strategy: Literal['none', 'start-end', 'time-interval']='time-interval', offset_intervals_minutes: list[int] = <factory>) → None#
__match_args__ = ('measurement_time_s', 'wait_time_s', 'additional_wait_time_s', 'pump_source', 'pump_power_mWcm2', 'auto_gain', 'auto_sensitivity', 'wavelengths_nm', 'energies_eV', 'offset_strategy', 'offset_intervals_minutes')#
__module__ = 'prsctrl.measurement.settings'#
__or__(other)#

Merge with another settings class or a dictionary. Unknown keys in a dictionary are ignored.

__replace__(**changes)#
__repr__()#

Return repr(self).

__static_attributes__ = ('energies_eV', 'wavelengths_nm')#
__weakref__#

list of weak references to the object

_get_dict(remove_empty_containers: bool = False, remove_None: bool = False, remove_if_None: list[str] | None = None) → dict#

Return the settings as a dictionary, optionally cleaning up the output.

Base implementation for get_dict(). Subclasses may call it with different arguments to configure the output.

Parameters:
  • remove_empty_containers – If True, remove empty dict, list, tuple or set values.

  • remove_None – If True, remove all keys with a None value.

  • remove_if_None – If given, remove these keys only if their value is None (absent keys are ignored).

Returns:

Instance converted to dictionary, see as_dict().

additional_wait_time_s: float = 0#
as_dict() → dict#

Convenience wrapper for dataclasses.asdict(self)

Returns all fields of the settings class. For a dictionary where certain fields may be skipped, see get_dict().

auto_gain: bool = False#
auto_sensitivity: bool = True#
copy() → Self#

Convenience method for copy.deepcopy(self)

energies_eV: tuple[float, float, float] | list[float] | None = None#
fields()#

Return a tuple describing the fields of this dataclass.

Adapted version of dataclass.fields that applies additional sorting of the fields according to the field’s metadata[“order”] parameter.

Accepts a dataclass or an instance of one. Tuple elements are of type Field.

classmethod from_dict(data: dict, strict: bool = False) → Self#

Recursively construct a SettingsClass from a dictionary.

If the value of a field is another SettingsClass, from_dict() will be called for that field as well. Handled are:

  • SettingsClass

  • list[SettingsClass]

  • dict[<any>, SettingsClass]

  • all of the above as Optional (Union with None)

  • a Union with any handled types

Parameters:

strict – If True, raise a KeyError on keys in data that are not field names of cls. Unknown keys are ignored otherwise.

Raises:
  • ValueError – If data contains a value that has the wrong type for the field of cls (ONLY if the type is a subclass of SettingsClass! Other types are not enforced)

  • KeyError – If strict is True and data contains a key that is not a field name of cls

get_dict() → dict#

Return the settings as a dictionary.

as_dict() returns the settings class with all fields, while get_dict() may be configured by subclasses to skip certain fields in the output. The default implementation returns all fields, like as_dict(). :return: Instance converted to dictionary.

get_metadata() → dict[str, Any][source]#

Return the measurements settings converted to a metadata dictionary that contains only relevant information.

Leaves out wavelengths and energies, as those will be contained in the data as columns anyways. Leaves out optional values that are set to None.

get_wavelengths_nm(round_to_digits: int | None = 2, update_field: bool = False) → list[float][source]#

Generate a list of wavelengths according to either the ‘wavelengths_nm’ or ‘energies_eV’ field.

Either field may already be a list of values, or a tuple (start, stop, step size).

Parameters:
  • round_to_digits – Optional number of digits to round the values to.

  • update_field – If True, overwrite the value of ‘wavelengths_nm’ with the returned array and ‘energies_eV’ with None.

Returns:

list of wavelengths in nm

get_wavelengths_nm_with_offsets(time_per_wavelength: int, round_to_digits: int | None = 2, update_field: bool = False) → list[float | str][source]#

Generate a list of wavelengths according to either the ‘wavelengths_nm’ or ‘energies_eV’ field and offset measurements.

Parameters:
  • time_per_wavelength – Estimated runtime per wavelength measurements. Required when offset_strategy==”time-interval”.

  • round_to_digits – Optional number of digits to round the values to.

  • update_field – If True, overwrite the value of ‘wavelengths_nm’ with the returned array and ‘energies_eV’ with None.

Returns:

list of wavelengths in nm and offset measurements

classmethod load_yaml(yaml_path: str, loader=<class 'yaml.loader.Loader'>)#
measurement_time_s: float = 30#
offset_intervals_minutes: list[int]#
offset_strategy: Literal['none', 'start-end', 'time-interval'] = 'time-interval'#
pump_power_mWcm2: float | None = None#
pump_source: str = 'none'#
save_yaml(yaml_path: str)#
wait_time_s: float | None = None#