spvctrl.data.util.save_pulse_hdf5#

save_pulse_hdf5(file_path: str | Path, U_spv: ndarray, U_diode: ndarray | None, sample_rate_Hz: float, n_pre_trigger: int, pulse_idx: int, compress: bool = False, compression_opts: int = 1, timestamp: str | None = None, conversion_spv: tuple[float, float] | None = None, conversion_diode: tuple[float, float] | None = None)[source]#

Save a full-resolution pulse transient to a plain hdf5 file.

The time axis is linear, so it is not stored: it is recalculated on load with t_s = (np.arange(n) - n_pre_trigger) / sample_rate_Hz.

If a conversion tuple (gain_V_per_count, offset_V) is given for a channel, the data of that channel is stored as raw ADC counts (datasets U_spv_raw/U_diode_raw, int16 for the Gage CompuScope) together with the conversion parameters in the file attributes. Otherwise the data is stored as float64 volt datasets U_spv_V/U_diode_V. Either both or no conversion must be given.

Parameters:
  • file_path – Path of the hdf5 file to write

  • U_spv – SPV channel values of the full recorded segment, including pre-trigger samples (raw ADC counts if a conversion is given, voltages otherwise)

  • U_diode – Diode channel values of the full recorded segment, including pre-trigger samples, or None when the diode channel is not recorded (no diode dataset is written)

  • sample_rate_Hz – Sample rate in Hz

  • n_pre_trigger – Number of pre-trigger samples, i.e. samples recorded before the trigger

  • pulse_idx – Pulse index, 0-based (-1 for averaged data)

  • compress – Whether to use gzip compression (with the byte-shuffle filter)

  • compression_opts – gzip compression level (1-9)

  • timestamp – Optional time of day string of the pulse

  • conversion_spv – (gain_V_per_count, offset_V) of the SPV channel, to store raw ADC counts

  • conversion_diode – (gain_V_per_count, offset_V) of the diode channel, to store raw ADC counts